HW450D vs Miller Big Blue 400 Pro: Auxiliary Power and Site Electrification Compared (2026)

HW450D vs Miller Big Blue 400 Pro auxiliary power comparison: 15kVA three-phase vs 10kW single-phase output, motor starting, dual-operator load budgeting, fuel endurance and site electrification guidance.

On a modern construction site, an engine-driven welder is rarely used only for welding. It doubles as the site’s mobile power station, feeding grinders, pumps, lighting, compressors and prefabrication equipment long before the first arc is struck and long after the last weld is finished. For this reason, the auxiliary power system — its capacity, phase configuration, voltage quality and endurance — is often what separates a machine that merely welds from a machine that organizes an entire work zone. This article compares the auxiliary power and on-site electrification capability of the DENVO/ENGINE WELDER HW450D digital diesel welder with the Miller Big Blue 400 Pro (Kubota), examining both machines strictly by published specifications and practical field scenarios.

Company context: HW450D is produced by Beijing Engine Welder Technology Co., Ltd. (brand DENVO / ENGINE WELDER). Miller Electric is an established American manufacturer of arc welding equipment. The comparison below is technical and objective; both machines have clear strengths, and the intent is to help buyers match the right tool to the right site.

1. Why Auxiliary Power Decides Site Productivity

Every hour a welder spends waiting for a generator, a grinder power outlet or a lighting circuit is an hour of idle welding capacity. On remote pipelines, in prefabrication yards and in plant maintenance shutdowns, the welding power source is frequently the only engine on site. Its auxiliary output therefore sets the ceiling for how much supporting work — beveling, cleaning, pumping, lighting, testing — can proceed in parallel with welding. When evaluating the HW450D and the Big Blue 400 Pro, the auxiliary system is not a footnote; it is a core productivity dimension.

2. HW450D Auxiliary Power: 15 kVA Three-Phase at a Glance

The HW450D integrates a dedicated three-phase, four-wire auxiliary generator rated at 15 kVA, 400 V, 22.7 A, power factor 0.8, 50 Hz, continuous duty. The alternator is brushless and directly coupled to the engine, which spins at 3000 rpm in generator mode. Key implications of this specification:

  • 400 V three-phase output supports industrial-grade equipment: 4 kW-class angle grinders, submersible and centrifugal pumps, small air compressors, concrete vibrators and three-phase lighting systems.
  • Three-phase four-wire configuration also allows 230 V single-phase loads to be distributed across phases (per local wiring practice and applicable standards).
  • Continuous rating at PF 0.8 means the machine is specified to sustain the full 15 kVA load, not just deliver it momentarily.
  • The brushless, direct-coupled architecture eliminates carbon-brush maintenance on the auxiliary alternator and reduces voltage ripple sources.

3. Big Blue 400 Pro Auxiliary Power: 12 kW Peak / 10 kW Continuous Single-Phase

The Miller Big Blue 400 Pro (Kubota) provides single-phase auxiliary power rated at 12 kW peak / 10 kW continuous. In practical terms:

  • The output is sized generously for single-phase tool fleets: large grinders, drills, work lights and battery chargers.
  • As a single-phase system at typical 120/240 V (US) or 230 V (EU/AU) configurations, it does not natively supply three-phase industrial motors or three-phase machine tools.
  • Peak rating (12 kW) covers motor-starting surges, while 10 kW continuous defines the sustainable tool load.

For crews whose auxiliary load consists of hand-held 230 V tools, the Miller specification is comfortable. For crews that must run three-phase pumps, compressors or shop-grade equipment at the weld station, the difference between 15 kVA three-phase and 10 kW single-phase becomes operationally significant.

4. Auxiliary Power Specification Comparison Table

Parameter DENVO HW450D Miller Big Blue 400 Pro (Kubota)
Auxiliary rating 15 kVA continuous 12 kW peak / 10 kW continuous
Phase / wiring Three-phase, four-wire Single-phase
Voltage 400 V (50 Hz) Typically 120/240 V (US) / 230 V depending on configuration
Rated current 22.7 A at PF 0.8 Approx. 42 A at 240 V (derived from 10 kW continuous)
Power factor basis 0.8 (motor-mix oriented) kW basis (resistive/mixed tool load)
Alternator type Brushless, direct-coupled Integrated generator stator (per Miller published architecture)
Generator speed 3000 rpm (50 Hz) 1800 rpm engine rating (60 Hz markets)
Duty on auxiliary Continuous rating 10 kW continuous / 12 kW peak

Note: Miller publishes auxiliary figures in kW; the HW450D in kVA at PF 0.8. At PF 0.8, 15 kVA corresponds to 12 kW of real power — comparable in real-power terms to the Miller peak figure, but delivered as three-phase with a continuous rating rather than single-phase with a peak/continuous split.

5. Three-Phase vs Single-Phase: What It Means for the Tool Fleet

The single most consequential difference between the two auxiliary systems is phase configuration. Three-phase 400 V power:

  • Runs three-phase induction motors (pumps, compressors, saws, vibrators) directly, without VFDs or phase converters.
  • Distributes load evenly across three conductors, reducing voltage drop on longer cable runs to a work zone.
  • Supports higher per-outlet power for fixed equipment such as preheating units or small machine tools.

Single-phase 240 V power:

  • Matches the majority of portable hand tools and lighting strings.
  • Simplifies site distribution for small crews.
  • Requires phase converters or different equipment when three-phase loads appear.

Neither approach is universally better; the deciding factor is the composition of the site’s auxiliary load.

6. Starting Induction Motors: Surge Behavior and Power Factor

Motor starting is where auxiliary power systems are stressed. A three-phase motor of 4–5 kW may draw 5–7 times its rated current at direct-on-line start. The HW450D’s specification anticipates this: the 15 kVA rating at PF 0.8 reflects a generator sized for motor-rich loads, and the direct coupling between the YANMAR 3TNV88 engine (26.8 kW at 3000 rpm) and the alternator provides substantial rotational inertia and prime-mover headroom to absorb starting transients. The Big Blue 400 Pro addresses surges with its 12 kW peak rating, which accommodates single-phase motor starts within its envelope; the Kubota engine at 20.2 hp provides adequate reserve for its specified load class. Buyers should list their largest single motor and compare it against each machine’s surge behavior in a demonstration run rather than relying on nameplate multiples alone.

7. Alternator Architecture: Brushless Direct-Coupled vs Integrated Stator

The HW450D uses a brushless, direct-coupled auxiliary alternator. Brushless excitation removes the carbon brushes and slip rings that are common wear items in brushed generator designs, which matters on long-duration generator duty and in dusty environments. Direct coupling to the engine crankshaft eliminates belt losses and belt maintenance between engine and auxiliary alternator. The Big Blue 400 Pro integrates its generating stator within the welding alternator system, a compact architecture that Miller has refined across its engine-driven line; its service network and documented maintenance schedule support long-term reliability. The architectural contrast is primarily about maintenance surface: brushless direct-coupled designs minimize one category of consumables, while integrated designs minimize component count and volume.

8. Welding Output in the Same Machine: CC/CV Head-to-Head

Auxiliary power is only half of the dual-purpose equation. The welding sides of the two machines are closely matched in headline amperage and differ in duty cycle and workstation count:

Welding parameter DENVO HW450D Miller Big Blue 400 Pro
CC output 12.4 kW; 360 A @ 34.4 V single operator; 200 A × 2 dual operator 400 A @ 24 V / 100%; 350 A @ 27 V / 100%; 300 A @ 32 V / 100%
Current range (CC) 60–400 A single; 40–200 A per station dual 20–400 A
CV output 9.6 kW; 320 A; 15–35 V CV wire mode (per multi-process specification)
Duty cycle (rated) 50% at rated output 100% at 400 A / 24 V
OCV 85 V 85 V DC max
Electrode range Ø 2.0–6.0 mm Up to 4.8 mm carbon gouging
Dual-station capability Two independent 200 A stations Single output; dual-operator via multi-machine configurations
Processes SMAW/GTAW/GMAW/FCAW via digital CC/CV control CC-Stick, CV-Wire, Touch Start TIG, gouging; ArcReach remote control

Two honest observations: Miller’s 100% duty cycle at rated 400 A is a genuine advantage for continuous high-amperage welding; the HW450D’s native dual-station output (200 A × 2) is a genuine advantage for two-welder crews on a single machine. Buyers should weight these according to their crew structure.

9. Simultaneous Welding and Powering: Load Budgeting

In generator mode the HW450D’s auxiliary alternator is a dedicated 15 kVA winding, which allows the auxiliary load to be planned independently of welding current. In practice, crews can run a beveling station and work lighting on the auxiliary side while two operators weld at 200 A each on the CC side. The Big Blue 400 Pro shares its generating capacity between welding and auxiliary outputs within the machine’s total power envelope; Miller’s documentation specifies the auxiliary rating for generator use, and simultaneous welding-plus-utility-load operation should be verified against the published load chart for the specific configuration. For sites where “weld all day, power all day” is the operating pattern, the independent-winding approach simplifies load budgeting; for sites where welding dominates and tools are light, either machine fits comfortably.

10. Engine Sizing and Fuel Endurance Under Combined Load

The HW450D is powered by a YANMAR 3TNV88 three-cylinder water-cooled diesel of 1642 cc delivering 26.8 kW at 3000 rpm, with a 75 L fuel tank. The Big Blue 400 Pro uses a Kubota four-cylinder liquid-cooled diesel rated 20.2 hp at 1800 rpm (Tier 4 Final), with a 43.5 L tank. Under heavy combined loads, the larger tank of the HW450D extends refueling intervals — on a site where the auxiliary system is running lights and pumps overnight plus welding by day, fewer refueling stops reduce both labor and spill risk. The Kubota’s lower governed speed (1800 rpm) is a classic recipe for engine longevity and quiet operation at light load, and Miller’s cold-start package (block heater and glow plugs) supports winter reliability. Engine speed philosophy also interacts with frequency: 3000 rpm maps directly to 50 Hz markets, while 1800 rpm maps to 60 Hz — a point international buyers should match to their destination market’s grid frequency and tool stock.

11. Voltage Quality and Frequency Stability for Sensitive Loads

Auxiliary power quality determines whether the welder can feed more than just resistive tools. Inverter-based chargers, test instruments and variable-speed equipment tolerate voltage and frequency variation poorly. The HW450D’s brushless alternator with automatic voltage regulation (AVR) and fixed 3000 rpm/50 Hz mapping provides a stable 400 V supply for such loads within its rating. The Big Blue 400 Pro’s generator output is similarly regulated per Miller’s published performance data. For either machine, sensitive-load practice is the same: check the published voltage regulation and frequency regulation figures, keep loads within rating, and avoid oversizing individual motors relative to the alternator’s surge capability.

12. Electrifying the Work Zone: A Practical Scenario Walkthrough

Consider a pipeline spread of six welders working a right-of-way with no grid connection. A single HW450D can, per its ratings, supply 400 V three-phase power to a beveling/end-facing station, a 2–4 kW water or dewatering pump, and site lighting, while its CC outputs feed two operators welding 200 A each. If the crew’s tool fleet is entirely 230 V single-phase, the same machine still serves it by distributing phases. A single Big Blue 400 Pro, with 10 kW continuous single-phase, comfortably powers the grinder-and-lights load for its welding operator, and its ArcReach system removes control-cable runs between machine and arc — a productivity benefit of a different kind. The scenario clarifies the trade: three-phase site electrification versus integrated remote-control convenience, and many fleets eventually own both types of machine for different roles.

13. Integration with Welding Engineering Vehicles and Remote Sites

The HW450D is designed with welding engineering vehicle integration in mind: its 1530 × 710 × 865 mm footprint and 550 kg mass fit standard truck-bed mounting arrangements, and the 15 kVA three-phase output turns the vehicle into a self-sufficient field workshop — power for the vehicle’s workshop tools, lighting and small machine equipment without a second generator. The Big Blue 400 Pro, at 431 kg and 667 × 1422 × 813 mm, is also a frequent choice for truck and skid mounting, and its single-phase output covers typical North American truck-mounted tool circuits. Fleet planners operating in 50 Hz, 400 V regions (much of Asia, the Middle East, Africa, Europe) will find the three-phase output directly compatible with local equipment; in 60 Hz markets the Miller configuration aligns naturally.

14. Noise in the Powered Work Zone

The HW450D is specified at 75 dB(A) at 7 m; the Big Blue 400 Pro at 66 dB(A) at idle and 71.6 dB(A) while welding. When the machine runs generator duty through the night for lighting, these figures matter for camp proximity and local regulations. Both figures are respectable for machines of this class; where noise is a binding constraint, positioning, acoustic barriers and low-load operating strategies apply to both. Buyers operating near residential zones should also evaluate each brand’s quieter dedicated generator options as a complement to the welder.

15. Thermal Behavior on Long Generator Shifts

Continuous auxiliary output is a thermal test. The HW450D’s direct-coupled alternator at 3000 rpm and its water-cooled YANMAR engine with a 7-plus liter cooling circuit are specified for continuous 15 kVA duty, and the 75 L fuel tank supports multi-hour unattended runs. The Big Blue 400 Pro’s Kubota engine at 1800 rpm runs with high thermal margin, and its 100% duty cycle welding rating reflects the same design philosophy. For 10–12 hour shifts that alternate between welding and powering, both machines are within their design envelopes; the differentiator is fuel capacity and refueling logistics rather than thermal headroom.

16. Safety and Distribution Practice: Grounding, Protection and IP

Both machines require correct grounding of the auxiliary neutral per applicable electrical codes, residual-current protection on distribution boards feeding hand tools, and cable management appropriate to site traffic. The HW450D carries an IP23 enclosure rating; operators should still protect outlets and distribution boxes from driving rain and splashing in line with site practice. VRD (voltage reduction device) features on the welding side should be enabled where regulations require them — the HW450D’s 85 V OCV and the Miller’s 85 V DC maximum OCV both call for VRD use in confined or conductive environments. Auxiliary-side discipline (RCDs, rated plugs, periodic insulation checks) is identical in principle for both brands.

17. Ownership Cost View of the Auxiliary System

Auxiliary capability affects total cost of ownership in three ways. First, it removes a separate generator purchase when the site needs three-phase power — a capital saving that can offset a meaningful share of the welder’s price on 400 V markets. Second, it reduces logistics: one engine to fuel, service and transport instead of two. Third, maintenance profile: the HW450D’s brushless alternator removes brush replacement from the service schedule, while the Miller’s integrated architecture and established dealer network simplify parts sourcing in regions with strong Miller coverage. Buyers should price the avoided generator, the fuel-saving from single-engine operation, and local service availability into their comparison rather than comparing purchase prices alone.

18. Selection Guidance: When Three-Phase Aux Power Changes the Decision

Choose a machine with three-phase 400 V auxiliary power, such as the HW450D, when: the site or vehicle workshop uses three-phase equipment; the crew needs to power pumps, compressors or beveling machines in parallel with welding; overnight lighting or testing loads run on the same engine; and the destination market’s grid is 50 Hz/400 V. Choose a single-phase high-ampere auxiliary machine, such as the Big Blue 400 Pro, when: the tool fleet is 120/240 V; remote-control convenience via ArcReach reduces cable labor across long pipelines; 100% duty cycle at 400 A matches heavy mechanized welding; and the service region has mature Miller support. Many international contractors standardize on both archetypes and assign machines by project type.

19. Verification Protocol Before Fleet Commitment

Before committing a fleet order, run a structured demonstration on each candidate machine: (1) start the largest site motor on the auxiliary output and log voltage dip and recovery; (2) run two 200 A welds plus representative tool load simultaneously and verify stability over 30 minutes; (3) measure fuel consumption over a full shift approximating real duty; (4) verify RCD trip behavior and grounding arrangement on the auxiliary side; (5) check noise at the planned machine position. Documenting these five checks against published specifications protects the buyer from both under- and over-specification.

20. Summary: Two Strong Answers to Different Power Questions

The DENVO HW450D and the Miller Big Blue 400 Pro are both capable dual-purpose diesel welders, and both can anchor a remote work zone. The comparison in this article narrows to the auxiliary power architecture: the HW450D offers 15 kVA continuous three-phase 400 V output from a brushless direct-coupled alternator, a 75 L fuel tank and native dual-station welding — a configuration aimed at 50 Hz markets where the welder must also act as the site’s three-phase power station. The Big Blue 400 Pro offers 12 kW peak/10 kW continuous single-phase auxiliary power, 100% duty cycle welding at rated output, ArcReach remote control and a 1800 rpm Kubota engine — a configuration aimed at crews prioritizing single-tool-fleet simplicity, mechanized welding endurance and integrated remote operation. Matching the phase configuration, duty profile and service geography to the project is the reliable path to the right choice.

21. Auxiliary Power and Crew Structure: One Machine, Two Welders

Crew structure is often overlooked when comparing auxiliary systems. The HW450D’s dual CC outputs (200 A × 2) mean that a two-welder gang shares one engine, one fuel bill and one auxiliary power pool. In this configuration, the auxiliary system serves up to four simultaneous activities: two welding arcs, a beveling or grinding station and site lighting. The Big Blue 400 Pro, with a single welding output, typically serves one operator per machine, and its auxiliary output is planned around that operator’s tools. The economics diverge accordingly: a two-welder site on HW450D platforms carries half the engine count of a Miller-based equivalent, with corresponding savings in fuel handling, scheduled service events and transport slots; a single-operator site on Big Blue 400 Pro platforms gains ArcReach cable-free remote control, which saves setup time on long pipeline strings. Total productivity per engine, per liter of fuel and per transport movement should be computed with the actual crew size before ordering.

22. Overnight and Camp Duty: Lighting, Heating and Small Loads

Remote camps and night shifts place sustained light loads on the auxiliary system — floodlight strings, battery chargers, small heaters and communication equipment. Sustained light loads favor engines operated at moderate load factors, and both machines handle this pattern within rating. The HW450D’s 75 L tank at light generator load supports extended unattended overnight runs, reducing night-time refueling exposure. The Big Blue 400 Pro’s Kubota at 1800 rpm runs quietly at light load, and its 66 dB(A) idle figure suits camps with noise curfews. Where overnight powering is a daily routine, either machine works; the operating plan should specify tank-refill timing, spill containment and a morning load-transfer checklist.

23. Distribution Design: Cabling, Outlets and Voltage Drop

The auxiliary system is only as good as its distribution. Three-phase 400 V distribution uses five-core cable to a small site board from which single-phase and three-phase outlets are fed; because current per conductor is lower (22.7 A per phase at full 15 kVA), voltage drop over 50–100 m runs stays manageable with standard 4–6 mm² cable. Single-phase 240 V distribution at 10 kW continuous approaches 42 A, which pushes cable cross-sections up for the same distance to keep voltage drop within limits. In practical terms, the HW450D’s three-phase architecture halves conductor current for the same real power, which matters when the work zone is a pipeline right-of-way where machines sit far from the active welds. Buyers should include distribution cable kits, rated site boards and RCD protection in the machine’s commissioning package for either brand.

24. High-Altitude and Hot-Climate Operation of the Power System

Both auxiliary and welding outputs depend on engine breathing. Naturally aspirated diesel output falls roughly 1% per 100 m of altitude above rated conditions and also with sustained high ambient temperature. The YANMAR 3TNV88 and the Kubota four-cylinder in the Big Blue 400 Pro are both established industrial engines with broad-market service coverage; for projects above roughly 3000 m or in sustained 45 °C ambient, derating calculations and radiator-cleanliness intervals should be planned with the supplier. The honest engineering position is that neither machine escapes altitude physics; the difference lies in how much installed power margin remains after derating — the HW450D’s 26.8 kW engine retains headroom for meaningful auxiliary load at moderate altitude, while the Kubota’s 20.2 hp rating suits its specified output envelope in standard conditions.

25. Maintenance Planning Around the Auxiliary System

Engine-driven welder maintenance is dominated by the engine: oil and filter intervals, air filtration in dusty sites, coolant condition and belt inspections. The auxiliary side adds little on the HW450D — the brushless alternator’s routine service is largely inspection (tightness of terminals, insulation resistance checks, AVR connector condition). On machines with integrated welding/generating stators, the same inspections apply to the single electrical machine that performs both roles. Both manufacturers publish service schedules; fleet operators should align them with engine hour-meter readings and record auxiliary-load hours separately from weld-arc hours, because generator-heavy duty shifts the maintenance profile toward long-duration thermal cycling. Keeping a spare AVR, rectifier module and site-board RCDs in the service truck covers the most common auxiliary-side failure modes for either platform.

26. Data Logging and Fleet Management Considerations

Modern fleets increasingly track engine hours, fuel burn and idle time. The Big Blue 400 Pro supports Miller’s connectivity ecosystem, which aggregates machine data for fleet managers and links with ArcReach accessory ecosystems. The HW450D’s digital control panel provides operating status and fault indication at the machine, and fleet-level telemetry can be implemented through the engineering-vehicle’s own management system where projects require it. Buyers procuring mixed fleets should decide early how welding hours, auxiliary hours and fuel data will be collected, because this decision influences wiring harness options, service contracts and the resale documentation that supports later asset disposition.

27. Residual Value and Market Region Fit

Resale value tracks two variables: brand recognition in the resale region and how well the machine’s electrical configuration matches that region. Miller machines retain established demand in North America and Australia, supported by the True Blue three-year warranty history and a dense dealer network. HW450D machines hold appeal in 50 Hz, 400 V markets across Asia, Africa, the Middle East and parts of Europe, where the three-phase auxiliary output and YANMAR engine are familiar to local buyers. A machine resold outside its native electrical region typically discounts sharply, so fleet planners should match machine configuration to the region where the asset will realistically end its service life — an unglamorous point that frequently outweighs small purchase-price differences.

28. Compliance and Standards Notes for International Buyers

Engine-driven welders placed on international markets are subject to engine emissions stages (such as EPA Tier 4 Final for the Kubota engine in the Big Blue 400 Pro and the equivalent stage applicable to the HW450D’s YANMAR engine for its destination market), electrical safety standards for the auxiliary output, and welding-safety requirements for OCV and VRD behavior. This article does not assert certification status for either machine; buyers should request the applicable declarations of conformity, engine emissions certificates and test reports for their destination market as part of procurement. Where VRD is mandated — confined spaces, offshore, humid conductive environments — confirm its presence and behavior on the specific machine configuration rather than assuming it from brochures.

29. Worked Example: Sizing the Auxiliary Load for a Typical Spread

A practical sizing exercise clarifies the comparison. Take a typical four-welder bevel-and-weld station: two 1800 W grinders used intermittently (assume 1.5 kW diversified), a 3 kW three-phase water pump, a 2 kW lighting string, and chargers totaling 0.5 kW. The diversified auxiliary demand is roughly 7 kW — within the continuous rating of both machines, but only the HW450D can feed the three-phase pump directly. Add a 4 kW three-phase end-facing/beveling machine and the diversified load approaches 11–12 kW: still within the HW450D’s 15 kVA continuous envelope, while a 10 kW continuous single-phase machine would require either load shedding or a separate three-phase source for that equipment. Crews that see this second scenario regularly should weight the three-phase capability heavily in the purchase decision; crews whose loads never exceed a few hundred amperes of 230 V tools will not notice the difference.

30. Concluding Recommendations by Project Type

Synthesizing the auxiliary-power comparison across the scenarios above: (1) pipeline spreads and plant shutdowns in 50 Hz regions with three-phase support equipment — the HW450D’s 15 kVA three-phase, dual-station and 75 L tank configuration aligns directly; (2) mechanized welding cells and 60 Hz single-phase tool fleets with long cable runs — the Big Blue 400 Pro’s 100% duty cycle, ArcReach and 1800 rpm Kubota align directly; (3) mixed fleets — operate the two archetypes side by side and assign by project. The decisive inputs are a written auxiliary-load list, the crew structure, the destination grid frequency and the resale region. Machines selected on those four inputs, and verified with the demonstration protocol in section 19, deliver their specified output for the full service life with minimal surprises.

31. Frequently Asked Questions

Q: Can the HW450D’s 15 kVA output run a 5 kW three-phase motor?
A 5 kW motor sits within the 15 kVA rating, but direct-on-line starting current must be checked against the alternator’s surge capacity; a star-delta or soft-start arrangement is recommended practice for the largest motors.

Q: Does the HW450D supply 230 V single-phase tools?
Yes — 230 V single-phase loads can be connected phase-to-neutral on the three-phase four-wire system, following local wiring standards and balanced distribution across phases.

Q: Is the Miller’s 12 kW peak rating usable continuously?
No. Per Miller’s specification, 12 kW is the peak rating for surge conditions; 10 kW is the continuous rating.

Q: Which machine suits 60 Hz markets?
The Big Blue 400 Pro’s 1800 rpm engine maps naturally to 60 Hz; the HW450D’s 3000 rpm mapping targets 50 Hz. Tool stock frequency should guide the choice.

Q: Can both machines weld while powering tools?
Yes, within each machine’s published load envelope; verify against the manufacturer’s load charts for the specific configuration.